Sn 2 mm
| Article number | Info | ||
|---|---|---|---|
| DW-AD-604-M12-120 Recommended | Inductive sensor M12 with 2 meters cable. Short housing. | Dimension: M12x35mm Output: PNP NC Connection: Straight cable Sensing distance: 2mm Flush mounting: Yes | ![]() |
| DW-AS-603-M12-120 Recommended | Inductive sensor M12 with M12 connector | Dimension: M12x45mm Output: PNP NO Connection: M12, 3-pol Sensing distance: 2mm Flush mounting: Yes | ![]() |
| AM1/AP-1A Recommended | Inductive sensor M12 with 2 meters cable | Dimension: M12x50mm Output: PNP NO Connection: Straight cable Sensing distance: 2mm Flush mounting: Yes | ![]() |
| DW-AS-603-M12 Recommended | Inductive sensor M12 with M12 connector | Dimension: M12x59mm Output: PNP NO Connection: M12, 3-pol Sensing distance: 2mm Flush mounting: Yes | ![]() |
| DW-AS-523-P12-630 Recommended | Inductive sensor. Extra thick ceramic front plate mounted with shrink fitting. The sensor can withstand pressures up to 500 bar (peaks at 1,000 bar) and has a very long lifespan. | Dimension: M12x56mm Output: PNP NO Connection: M12, 3-pol Sensing distance: 2,5mm Flush mounting: Yes | ![]() |
| DW-AD-603-M12-120 | Inductive sensor M12 with 2 meters cable. Short housing. | Dimension: M12x35mm Output: PNP NO Connection: Straight cable Sensing distance: 2mm Flush mounting: Yes | ![]() |
| DW-AS-604-M12-120 | Inductive sensor M12 with M12 connector. Short housing. | Dimension: M12x45mm Output: PNP NC Connection: M12, 4-pol Sensing distance: 2mm Flush mounting: Yes | ![]() |
| AM1/AP-1C Recommended | Inductive sensor M12 with 2 meters cable. Radial cable output. | Dimension: M12x50mm Output: PNP NO Connection: Angled cable Sensing distance: 2mm Flush mounting: Yes | ![]() |
| DW-AD-603-M12 | Inductive sensor M12 with 2 meters cable | Dimension: M12x50mm Output: PNP NO Connection: Straight cable Sensing distance: 2mm Flush mounting: Yes | ![]() |
| DW-AD-607-M12 | Inductive sensor M12 with 2 meters cable | Dimension: M12x50mm Output: AC/DC NO Connection: Straight cable Sensing distance: 2mm Flush mounting: Yes | ![]() |
| AM6/AP-1H | Inductive sensor M12 with M12 connector | Dimension: M12x53mm Output: PNP NO Connection: M12, 3-pol Sensing distance: 2mm Flush mounting: Yes | ![]() |
| IDWE-P12MC-NMS-A0-100 | Smart Sensor for high pressures, with two programmable outputs. Continuous identification, programming, and diagnostics via IO-Link with Smart Sensors Profile. Extra thick ceramic front plate mounted with shrink-fitting. The sensor withstands pressures up to 500 bar (spikes 1,000 bar) and has a very long service life. | Dimension: M12x56mm Output: 2xPNP Connection: M12, 4-pol Sensing distance: 0-2mm Flush mounting: Yes | ![]() |